Description
The fully sealed oil-immersed type transformer has the advantages of low loss, low noise, and high efficiency, and can achieve good energy saving effect and reduce pollution. Compared with the ordinary oil-immersed transformer, the fully-sealed oil-type transformer cancels the oil storage tank, and the change of oil volume is automatically adjusted and compensated by the elasticity of the corrugated sheet of the corrugated oil tank. The transformer is isolated from the air, preventing and slowing down the deterioration of oil and insulation aging. , Enhanced operational reliability, maintenance-free normal operation.
Oil Immersed Type Transformer Details
Support customization
Real material, maintenance-free, low loss, economical operation;
Insulation sleeve
Improve product insulation and enhance the ability to resist breakdown;
Oil-level metering device
High measurement accuracy, accurate data, red means insufficient oil, blue means normal operation;
Heat sink design
The sealed design is adopted to dissipate heat evenly and increase the overload capacity of the transformer;
Oil-Filled Type Transformers Parameter
Rated Capacity (kva) | Voltage combination (kv) | Linkage group label | Loss | No-load current% | Short circuit impedance% | Dimensions(mm) | Installation size(mm) | |||
High pressure(kv) | Tap range | Low pressure | No load | Load | ||||||
30 |
6 6.3 6.6 10 10.5 11 |
0.4 |
Dyn11
Yyn0 |
100 | 630 | 2.3 | 4 | 740x500x930 | 400×400 | |
50 | 130 | 910 | 2.0 | 800x500x1040 | ||||||
80 | 180 | 1310 | 1.9 | 840x620x1100 | ||||||
100 | 200 | 1580 | 1.8 | 1060x640x1110 | 550×550 | |||||
160 | 280 | 2310 | 1.6 | 1160x720x1200 | ||||||
200 | 340 | 2730 | 1.5 | 1200x730x1220 | ||||||
250 | 400 | 3200 | 1.4 | 1260x810x1260 | ||||||
315 | 480 | 3830 | 1.4 | 1260x780x1330 | ||||||
400 | 570 | 4520 | 1.3 | 1360x860x1400 | 660×660 | |||||
500 | 680 | 5410 | 1.2 | 1400x920x1400 | ||||||
630 | 810 | 6200 | 1.1 | 4.5 | 1560x970x1500 | |||||
800 | 980 | 7500 | 1.0 | 1600x1010x1520 | 820×820 | |||||
1000 | 1150 | 10300 | 1.0 | 1620x1060x1560 | ||||||
1250 | 1360 | 1200 | 0.9 | 1740x1120x1650 | ||||||
1600 | 1640 | 14500 | 0.8 | 1800x1180x1750 |
Oil Type Transformer Structural Features
Iron core: All are made of high-quality high-permeability grain-oriented cold-rolled silicon steel sheets, fully oblique and non-porous binding structure, and the iron core is multi-level stepped, with three, five, or seven seams, low air loss, and low noise.
Coil: It is made of high-quality QQ acetal enameled copper wire, flat copper wire, or copper foil is drawn by an oxygen-free copper rod, and its forms include cylindrical type, continuous type, new spiral type, split type, etc., with Sufficient electrical strength, mechanical strength, and heat dissipation capacity.
Fuel tank: It is welded by high-quality steel plates, with elliptical, rectangular, and other structures. The heat dissipation element adopts a sheet radiator or corrugated fuel tank. The fuel tank has undergone a reliable sealing test in the factory. Carry out three-bottom and one-sided paint coating, which is both corrosion-resistant and beautiful.
Oil-Immersed Transformers Conditions Of Use
1. Wind speed: <35m/s
2. Altitude of use: H<1000m
3. Working environment temperature: -25℃~+40℃
4. Earthquake acceleration: horizontal acceleration is 0.4m/s2
5. Workplace: no fire, explosion hazard, severe vibration of chemical corrosion level
6. Relative humidity: When the air is at +25°C, the relative humidity should not exceed 90%
The oil-immersed transformer is an important piece of electrical equipment with excellent insulation performance and cooling performance. It plays a key role in the transmission and distribution of electric energy in the power system, improving the reliability and security of the power grid. As the demand for electricity grows, oil-immersed transformers will continue to play an important role in driving the development of power systems.